Model NO.: BS-102
Power Output: 3kw
X-ray Tube: Fixed Anode Max Height
Rectifier Method: Full-Wave Rectifier
Tube Voltage: 40~90kv 9steps
Tube Current: 50~90kv 15mA 50~90kv 30mA 40~80kv 50mA
Photography Time: 50~90kv 15mA 0.1~6.3s 50~90kv 30mA 0.1~6.3s
Power Supply: 220V&Plusmn
Operation Methods: Wire Control/Wireless Control (20m)
Adavantage: Multifunctional Cassette Storage Box Design
Generator: High Quality X-ray Generator, Excellent X-ray Sour
Trademark: Bisen
Transport Package: Standard Export Wooden or Thick Carton Packing
Specification: 199/137KG
Origin: China, Guangzhou
BS-102 Top Brand in China Medical Mobile X Ray Machine for Diagnostic Fluoroscopy
BS-102 Top Brand In China Medical Mobile X Ray Machine For Diagnostic Fluoroscopy 
BS-102 Top Brand in China Medical Mobile X Ray Machine for Diagnostic Fluoroscopy

Features:

1. Using ergonomic design, the structure is of compact appearance, convenient operation.

2. It adopts high pressure-resistant electrical tube with enough kV and mA, so the definition and contrast of the machine are good.

3. With combined X-ray generator, the tube and rocker can move up and down freely. So the patient can take photography in a wider range of direction.

4. Because of symmetrical adjustable beam limiting device with light source, the x-ray beam can be adjusted according to demands.

5. X-ray generator is matched with protective stereotype inside, and 10 meters wireless remote control exposure is adopted, so it causes less hurt to the operators and environment.

6. The current has three gears (15mA, 30mA, 50mA), different current can be selected according to different photography requirements, thus using range of machine is wider.

7. Anti-electric shock, anti scattering and full-wave rectifier

8. The electric performance is stable and reliable. Multi-protections are adopted to prevent over-voltage, over-current and output overload etc., so it's safer.

9. Telescopic vertical rotating angle is larger than 60°.

Usage:

The machine is mobile X-ray radiography medical diagnostic equipment. It can be used in wards, operation rooms and emergency rooms etc., and it can satisfy the radiography requirements of human body such as head, chest and limbs.