Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with Ce

Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with Ce

Model NO.: MCL-301 Semi Auto Chemistry analyzer
Clinical Chemistry Analyzer: Best Service
Absorbance Range: -0.214~3.000
Absorbance Resolution: 0.0001
Absorbance Linearity: ±1%
Absorbance Repeatability: ±0.001
Precision: ≤1.0%
Carry Over: ≤1%
Blood Chemistry Analyzer: Temperature 25,30,37,±0.3
Trademark: MeCan
Transport Package: Standard Packing for Export
Specification: CE for all of our chemistry analyzers
Origin: Guangzhou China
Model NO.: MCL-301 Semi Auto Chemistry analyzer
Clinical Chemistry Analyzer: Best Service
Absorbance Range: -0.214~3.000
Absorbance Resolution: 0.0001
Absorbance Linearity: ±1%
Absorbance Repeatability: ±0.001
Precision: ≤1.0%
Carry Over: ≤1%
Blood Chemistry Analyzer: Temperature 25,30,37,±0.3
Trademark: MeCan
Transport Package: Standard Packing for Export
Specification: CE for all of our chemistry analyzers
Origin: Guangzhou China
Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with CE
 
Semi-Auto Chemistry Analyzer  
Model: MCL-301 
  
Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with Ce
 
6 detecting wavelengths: 450-492-510-546-578-630nm
Up to 70 test items
Analytical modes: end-point, absorbance.
Large LCD. menu operation, hospital and patient information editing available
Inner thermal-sensitive printer. English comprehensive report available, including refer range
Memory for 10000 sample results
Few reagent needing, low detecting cost.
Open reagents 
 
Specification of the chemistry analyzer:
Test project ≥70
Wavelength 450,492,510,546,578,630nm
Flow cell 32uL,quartz glass
Liquid volume 200-3000uL
Resolution 0.001Abs(display),0.0001Abs(calculation)
Carryover <1%
Repeatability <1%
Printer Internal thermal-sensitive printer, 58nm paper width
Display 240*64LCD
Communication RS-232 serial cable
Power supply 220\110VAC±15%,50\60Hz 80W
Temperature 15ºC-30ºC wet≤90%
Dimension 380mm(L)*330mm(W)160mm(H)
Weight 7Kg
 
******************************************************************************************************************
Semi-Auto Chemistry Analyzer 
Model 2 : MCL-302B   (Most Populer Semi-auto model)            

Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with Ce
Feature of the Biochemistry analyzer 
7 inch Color LCD , Touch screen 
Flow cell and Cuvette test mode compatible 
Real time curve showing 
7 wavelength , 90 test item pre-programmed
Memory for 10,000 sample results
Light source hibernate function making lamp life longer 
RS232 interface, PC connecting
 
Specification of the Semi-auto chemistry analyzer:
Test mode: Kinetic, End point, Two point, Absorbance
Wavelength: 7 standard filters, 340, 405, 492, 510, 546, 578, 630 nm, 1 free position 
Wavelength precision: ±2 nm, width ≤ 10nm
Absorbance range: 0~4.500 Abs
Absorbance precision: outside 0.0001 Abs , inside 0.00001 Abs
Carry over: < 1%
Repeatability CV: < 1%
 
Incubator: 37ºC, 30ºC, 25ºC, Precision : ±0.1ºC
Sample volume: 0~3000 uL (≥500uL recommend) 
Data Storage: ≥10000
Quality control curve: SD, CV%, L-J quality control curve for every test item
Flow cell: 32 uL quartz glass, 10 mm
Lamp: Philips 6V 10W Halogen Lamp with long life 
Screen: 7 inch color LCD 
CPU: ARM series high speed micro CPU 
Printer: Internal thermal sensitive printer
Interface: RS-232 
Work Environment: Temperature 0ºC ~ 40ºC, Humidity: ≤80% 
Power supply: 100~240VAC, 50-60Hz, 100VA
Dimension: 340(L)*270(W)*160(H)
Weight: 5 kg
 
Usual test list of the chemistry analyzer:
Liver function: ALT  AST  ALP  T-BIL  D-BIL  TP  ALB  TTT  CHE  Nh3
Renal function : BUN  CRE  UA  URE  CO2-CP  γ-GT
Lipids: T-CHO  TG  HDL-C  LDL-C
Cardiac function: CK  CK-MB  LDH
Immune proteins: IGA  IGG  IGM  C3
Others: GLU  HGB  AMS
 
****************************************************************************************************
200 Tests/hour Fully Automatic Chemistry analyzer
Model: MCL-1020  (Most Popular & Offertable Fully-Auto Type)

Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with Ce
Overall Performance of the fully automatic chemistry analyzer:
Equipment type        Fully automatic discrete, STAT priority
Analysis rate          Constant speed 200T/H (without ISE)
Test principle          Colorimetry, turbidimetry
Analysis method       End-point, 2 kinetics, fixed-time, etc. support single/double wavelength, linear and non-linear calibration
 
Reagent System
Reagent Tray         25 reagent positions
Reagent Volume      R1:25-300ul, R2:10-150ul, 0.1ul increment
Reagent Probe        Liquid level detection, the remaining detection, collision protection etc.
Reagent Refrigeration    4-15ºC, independent power supply, 24-hour non-stop refrigeration
 
Sample System
Sample Tray          42 sample positions, random access of all samples
Sample Volume       2-50ul, 0.1ul increment
Sample probe         Liquid level detection, the remaining detection, collision protection etc.
Sample Containers    Sample cups, Micro tube, Original blood-collection tube, etc.
 
Reaction System
Reaction Tray        Rotating tray, 120 cuvettes
Cuvette             Reusable high quality cuvette, Optical diameter 6mm
Reaction Volume     180-500ul
Incubation system    Bi-directional liquid-air device
Temperature         37ºC±0.1ºC with real-time display
 
Optical System
Light source           12V35W halogen lamps, over 2000 hours
Photoelectron road     after spectrophotometry
Wavelength           340,405,450,510,546,578,630,700nm
Absorbance range     0-3.500Abs
Resolution            0.0001Abs
 
Working Conditions of the fully automatic biochemistry analyzer:
Power supply             AC 220V±22V, 50Hz±1Hz, power 1.5KVA
Ambient Temperature     15-30 ºC
Humidity                 35-80%
Water consumption        5L/Hour
Dimension                Bench top: 750mm*520mm*600mm
Weight                   45KG
 
Operating System
PC operating system       Windows XP or above
Analysis control software      English version graphical operating software
Report printing            Report formats support the user-defined mode, QC and state information etc.
System connection        RS-232

Wecome to contact us for USD699 Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with CE.
 
Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with CE
 
Semi-Auto Chemistry Analyzer  
Model: MCL-301 
  
Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with Ce
 
6 detecting wavelengths: 450-492-510-546-578-630nm
Up to 70 test items
Analytical modes: end-point, absorbance.
Large LCD. menu operation, hospital and patient information editing available
Inner thermal-sensitive printer. English comprehensive report available, including refer range
Memory for 10000 sample results
Few reagent needing, low detecting cost.
Open reagents 
 
Specification of the chemistry analyzer:
Test project ≥70
Wavelength 450,492,510,546,578,630nm
Flow cell 32uL,quartz glass
Liquid volume 200-3000uL
Resolution 0.001Abs(display),0.0001Abs(calculation)
Carryover <1%
Repeatability <1%
Printer Internal thermal-sensitive printer, 58nm paper width
Display 240*64LCD
Communication RS-232 serial cable
Power supply 220\110VAC±15%,50\60Hz 80W
Temperature 15ºC-30ºC wet≤90%
Dimension 380mm(L)*330mm(W)160mm(H)
Weight 7Kg
 
******************************************************************************************************************
Semi-Auto Chemistry Analyzer 
Model 2 : MCL-302B   (Most Populer Semi-auto model)            

Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with Ce
Feature of the Biochemistry analyzer 
7 inch Color LCD , Touch screen 
Flow cell and Cuvette test mode compatible 
Real time curve showing 
7 wavelength , 90 test item pre-programmed
Memory for 10,000 sample results
Light source hibernate function making lamp life longer 
RS232 interface, PC connecting
 
Specification of the Semi-auto chemistry analyzer:
Test mode: Kinetic, End point, Two point, Absorbance
Wavelength: 7 standard filters, 340, 405, 492, 510, 546, 578, 630 nm, 1 free position 
Wavelength precision: ±2 nm, width ≤ 10nm
Absorbance range: 0~4.500 Abs
Absorbance precision: outside 0.0001 Abs , inside 0.00001 Abs
Carry over: < 1%
Repeatability CV: < 1%
 
Incubator: 37ºC, 30ºC, 25ºC, Precision : ±0.1ºC
Sample volume: 0~3000 uL (≥500uL recommend) 
Data Storage: ≥10000
Quality control curve: SD, CV%, L-J quality control curve for every test item
Flow cell: 32 uL quartz glass, 10 mm
Lamp: Philips 6V 10W Halogen Lamp with long life 
Screen: 7 inch color LCD 
CPU: ARM series high speed micro CPU 
Printer: Internal thermal sensitive printer
Interface: RS-232 
Work Environment: Temperature 0ºC ~ 40ºC, Humidity: ≤80% 
Power supply: 100~240VAC, 50-60Hz, 100VA
Dimension: 340(L)*270(W)*160(H)
Weight: 5 kg
 
Usual test list of the chemistry analyzer:
Liver function: ALT  AST  ALP  T-BIL  D-BIL  TP  ALB  TTT  CHE  Nh3
Renal function : BUN  CRE  UA  URE  CO2-CP  γ-GT
Lipids: T-CHO  TG  HDL-C  LDL-C
Cardiac function: CK  CK-MB  LDH
Immune proteins: IGA  IGG  IGM  C3
Others: GLU  HGB  AMS
 
****************************************************************************************************
200 Tests/hour Fully Automatic Chemistry analyzer
Model: MCL-1020  (Most Popular & Offertable Fully-Auto Type)

Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with Ce
Overall Performance of the fully automatic chemistry analyzer:
Equipment type        Fully automatic discrete, STAT priority
Analysis rate          Constant speed 200T/H (without ISE)
Test principle          Colorimetry, turbidimetry
Analysis method       End-point, 2 kinetics, fixed-time, etc. support single/double wavelength, linear and non-linear calibration
 
Reagent System
Reagent Tray         25 reagent positions
Reagent Volume      R1:25-300ul, R2:10-150ul, 0.1ul increment
Reagent Probe        Liquid level detection, the remaining detection, collision protection etc.
Reagent Refrigeration    4-15ºC, independent power supply, 24-hour non-stop refrigeration
 
Sample System
Sample Tray          42 sample positions, random access of all samples
Sample Volume       2-50ul, 0.1ul increment
Sample probe         Liquid level detection, the remaining detection, collision protection etc.
Sample Containers    Sample cups, Micro tube, Original blood-collection tube, etc.
 
Reaction System
Reaction Tray        Rotating tray, 120 cuvettes
Cuvette             Reusable high quality cuvette, Optical diameter 6mm
Reaction Volume     180-500ul
Incubation system    Bi-directional liquid-air device
Temperature         37ºC±0.1ºC with real-time display
 
Optical System
Light source           12V35W halogen lamps, over 2000 hours
Photoelectron road     after spectrophotometry
Wavelength           340,405,450,510,546,578,630,700nm
Absorbance range     0-3.500Abs
Resolution            0.0001Abs
 
Working Conditions of the fully automatic biochemistry analyzer:
Power supply             AC 220V±22V, 50Hz±1Hz, power 1.5KVA
Ambient Temperature     15-30 ºC
Humidity                 35-80%
Water consumption        5L/Hour
Dimension                Bench top: 750mm*520mm*600mm
Weight                   45KG
 
Operating System
PC operating system       Windows XP or above
Analysis control software      English version graphical operating software
Report printing            Report formats support the user-defined mode, QC and state information etc.
System connection        RS-232

Wecome to contact us for USD699 Semi Automatic Blood Chemistry Analyzer Clinical Biochemistry Analyzer with CE.
 

Lab Glassware

High Quality Condoms Mould,Glass Mould For Condom ,Condoms Mould

Glass Ampoule,Caps Or Seals,Moulded Vials Co., Ltd. , http://www.ns-pharmaceutical.com