Human Angiopoietin-2 ELISA Kit Instructions for Use

Human Angiopoietin-2 ELISA Kit Instructions for Use

Human Angiopoietin-2 ELISA Kit
  ( used in other biological fluids such as serum, plasma, cell culture supernatant, and saliva )
principle
This experiment used double antibody sandwich ABC-ELISA. The anti-human Angiopoietin-2 mAb was coated on the plate, the Angiopoietin-2 in the standard and the sample was combined with the mAb, and biotinylated anti-human Angiopoietin-2 was added to form an immune complex attached to the plate. Horseradish peroxidase-labeled Streptavidin is combined with biotin, the substrate working solution is blue, and finally the stop solution sulfuric acid is added. The OD value is measured at 450 nm. The concentration of Angiopoietin-2 is directly proportional to the OD value, which can be drawn by standard. The curve was used to determine the concentration of Angiopoietin-2 in the specimen.
Kit composition ( 2-8 ° C preservation)
Coated Wells
96 holes
Enzyme Conjugate
12ml
10× specimen dilution (Sample Buffer)
12ml
20×Wash Buffer
50ml
Standards: 4ng/bottle
2 bottles
Substrate working fluid (TMB Solution)
12ml
Primary antibody working solution (Biotinylated Antibody)
12ml
Stop Solution
12ml
Prepare reagents and collect blood samples
1. Collection of specimens: serum, plasma (EDTA, citrate, heparin anticoagulation), cell culture supernatant, saliva, tissue homogenate, etc., as soon as possible, stored at 2-8 ° C for 48 hours; longer time must be frozen (- 20 °C or -70 °C) Save to avoid repeated freezing and thawing. Serum, plasma, cell culture supernatant with sample dilution is 1:10 dilution (2OuI taken, added 180ul sample dilutions, diluted 10 times). Saliva is not diluted and tested directly.
2. Standard product preparation: Add 0.5ml distilled water before use and mix well to form a solution of 8000pg/ml. Set 8 tubes of standard tube, and add 200 ul of standard dilution solution to each tube. Add 200 ul of the standard solution of 8000 pg/ml to the first tube, mix and aspirate 200 ul with the sampler, and transfer to the second tube. Repeat the dilution as described above, and aspirate 200 ul from the seventh tube and discard it. The eighth tube is a blank control.
3. The 10× specimen dilution was diluted 1:10 with distilled water (example: 1 ml concentrated dilution + 9 ml distilled water).
4. Washing solution: diluted 1:20 with distilled water (example: 1 ml concentrated washing solution added to 19 ml of distilled water)
Test procedure
1. Loading: Add 100 ul of standard or sample to be tested in each well. Mix the reaction plate thoroughly and let it stand at 37 °C for 120 minutes.
2. Wash the plate: Wash the plate thoroughly with washing solution 4-6 times, and dry it on the filter paper.
3. Add 100 ul of the first antibody working solution to each well. The reaction plate was thoroughly mixed and placed at 37 ° C for 60 minutes.
4. Wash the board: the same as before.
5. Add 100 ul of enzyme-labeled antibody working solution per well. The reaction plate was placed at 37 ° C for 30 minutes.
6. Wash the board: same as before.
7. Add 100 ul of substrate working solution per well, set 37 The reaction was carried out in the dark at °C for 15 minutes.
8. Add 100 ul of stop solution to each well and mix.
9. Measure the absorbance at 450 nm using a microplate reader within 30 minutes.
Result calculation and judgment
1. All OD values ​​should be subtracted from the blank value before calculation.
2. Take the standard products 4000, 2000, 1000, 500, 250, 125, 62.5, 0 pg/ml as the abscissa and OD as the ordinate. Draw on the coordinate paper and draw the standard curve.
3. According to the sample OD value, find the corresponding Angiopoietin-2 content on the graph, and then multiply the dilution factor.
Kit performance
1. Sensitivity: The minimum Angiopoietin-2 assay concentration is less than 31 pg/ml.
2. Specificity: The recombinant or natural human Angiopoietin-2 can be detected simultaneously. Does not cross-react with other human cytokines.
3. Repeatability: The coefficient of variation in both the plate and the plate is less than 10%.
Precautions
1. It is recommended to make double holes for the above standard holes and samples to be tested. The standard curve should be made at the same time for each measurement.
2. The washing process is critical. Insufficient washing will result in an accuracy error and an erroneous rise in the OD value.
3. After the slats are opened, the remaining slats should be sealed again to keep the slats dry .
4. This kit should be stored in a 4 o C refrigerator.
5. This kit is for scientific research only and cannot be used for clinical diagnosis!

Herbal Extract

We are a professional manufacturer and exporter in different kinds herbal powder extraction and liquid extraction.any extraction you need,pls.feel free to contact us.we'd like to cooperation with your esteemed companay.good commodity,resonable price and good service always is the aim we work for you.

Herbal Extract,Liquid Extract